Applying Drives to Single-Phase Input Application
247
8.3
Input Frequency and Voltage Tolerance
The single-phase current ratings are valid for 60Hz input only. The AC supply voltage must
be within the required voltage range of 240/10% to –5% to maximize motor power
production. Standard product with three-phase voltage input has an allowable range of +10%
to –15%. Therefore, a stricter input voltage tolerance of +10 to –5% applies when using the
drive with a single-phase supply. The average bus voltage with single-phase input is lower
than the equivalent of a three-phase input. Therefore, the maximum output voltage (motor
voltage) will be lower with a single-phase input. The minimum input voltage must be no less
than 228Vac for 240 volt models and 456Vac for 480 volt models, to ensure motor voltage
production of 207Vac and 415Vac, respectively. Thus, if full motor torque must be
developed near base speed (full power) it will be necessary to maintain a rigid incoming line
voltage so that adequate motor voltage can be produced. Operating a motor at reduced
speed (reduced power), or using a motor with a base voltage that is lower than the
incoming AC supply rating (ex. 208Vac motor with a 240Vac supply), will also minimize the
effect of voltage deprivation. (240VAC Input
208V motor, 480VAC Input
400V motor)
Summary of Contents for LSLV-S100 Series
Page 1: ......
Page 11: ...Preparing the Installation 2 ...
Page 13: ...Preparing the Installation 4 5 5 22kW 3 Phase ...
Page 16: ...Preparing the Installation 7 Front cover removed ...
Page 45: ...Installing the Inverter 36 IP66 0 4 0 8kW 3 phase 1 5 2 2kW 3 phase ...
Page 50: ...Installing the Inverter 41 0 4 22kW Standard I O Multiple I O ...
Page 67: ...Installing the Inverter 58 ...
Page 69: ...Learning to Perform Basic Operations 60 30 75kW Models ...
Page 193: ...Table of Functions 184 ...
Page 205: ...196 Troubleshooting ...
Page 228: ...Technical Specification 219 30 75kW Models 30 kW 3 Phase 37 45 kW 3 Phase ...
Page 230: ...Technical Specification 221 IP66 Models 0 4 4 0kW NP Non PDS type ...
Page 231: ...Technical Specification 222 0 4 4 0kW PDS type ...
Page 233: ...Technical Specification 224 5 5 7 5kW NP Non PDS type ...
Page 235: ...Technical Specification 226 11 0 22 0kW NP Non PDS type ...
Page 259: ...250 ...
Page 261: ...252 ...
Page 263: ...254 ...