Installing the Inverter
43
Function
Label
Name
Description
frequency
reference input
Switch between voltage (V2) and current (I2)
modes using a control board switch (SW2).
V2 Mode:
•
Unipolar: 0–10V (12V Max.)
I2 Mode
•
Input current: 4–20mA
•
Maximum Input current: 24mA
•
Input resistance: 249Ω
TI
Pulse input for
frequency
reference input
(pulse train)
Setup or modify frequency references using
pulse inputs from 0 to 32kHz.
•
Low Level: 0–2.5V
•
High Level: 3.5–12V
(In case of Standard I/O, Pulse input TI and Multi-
function terminal P5 share the same terminal. Set
the ln.69 P5 Define to 54(TI).).
Safety
functionality
configuration
SA
Safety input A
Used to block the output from the inverter in an
emergency.
Conditions:
•
Normal Operation: Both the SA and SB
terminals are connected to the SC terminal.
•
Output Block: One or both of the SA and SB
terminals lose connection with the SC
terminal.
SB
Safety input B
SC
Safety input
power source
DC 24V, < 25mA
Summary of Contents for LSLV-S100 Series
Page 1: ......
Page 11: ...Preparing the Installation 2 ...
Page 13: ...Preparing the Installation 4 5 5 22kW 3 Phase ...
Page 16: ...Preparing the Installation 7 Front cover removed ...
Page 45: ...Installing the Inverter 36 IP66 0 4 0 8kW 3 phase 1 5 2 2kW 3 phase ...
Page 50: ...Installing the Inverter 41 0 4 22kW Standard I O Multiple I O ...
Page 67: ...Installing the Inverter 58 ...
Page 69: ...Learning to Perform Basic Operations 60 30 75kW Models ...
Page 193: ...Table of Functions 184 ...
Page 205: ...196 Troubleshooting ...
Page 228: ...Technical Specification 219 30 75kW Models 30 kW 3 Phase 37 45 kW 3 Phase ...
Page 230: ...Technical Specification 221 IP66 Models 0 4 4 0kW NP Non PDS type ...
Page 231: ...Technical Specification 222 0 4 4 0kW PDS type ...
Page 233: ...Technical Specification 224 5 5 7 5kW NP Non PDS type ...
Page 235: ...Technical Specification 226 11 0 22 0kW NP Non PDS type ...
Page 259: ...250 ...
Page 261: ...252 ...
Page 263: ...254 ...