93
Learning to Perform Basic Operations
Step
Instruction
Keypad Display
9
Press the [
▲
] key to change it to 2 (Potentiometer), and
then press the [ENT] key.
The new parameter value will flash.
10
Press the [ENT] key once again.
The Frq code is displayed again. The frequency input
has been configured for potentiometer.
11
Press the [
▼
] key 4 times.
Returns to the first code of the Operation group (0.00).
From here frequency setting values can be monitored.
12
Adjust the potentiometer to increase or decrease the
frequency reference to 10Hz.
-
13
Press the [RUN] key on the keypad.
The RUN indicator light flashes and the FWD indicator
light comes on steady. The current acceleration
frequency is displayed.
14
When the frequency reaches the reference (10Hz),
press the [STOP/RESET] key on the keypad.
The RUN indicator light flashes again and the current
deceleration frequency is displayed. When the frequency
reaches 0Hz, the RUN and FWD indicator lights turn off,
and the frequency reference (10.00Hz) is displayed
again.
[Wiring Diagram]
[Operation Pattern]
Note
The instructions in the table are based on the factory default parameter settings. The inverter
may not work correctly if the default parameter settings are changed after the inverter is
purchased. In such cases, initialize all parameters to reset the factory default parameter
settings before following the instructions in the table.
@
frq
0.00
Summary of Contents for LSLV-S100 Series
Page 1: ......
Page 11: ...Preparing the Installation 2 ...
Page 13: ...Preparing the Installation 4 5 5 22kW 3 Phase ...
Page 16: ...Preparing the Installation 7 Front cover removed ...
Page 45: ...Installing the Inverter 36 IP66 0 4 0 8kW 3 phase 1 5 2 2kW 3 phase ...
Page 50: ...Installing the Inverter 41 0 4 22kW Standard I O Multiple I O ...
Page 67: ...Installing the Inverter 58 ...
Page 69: ...Learning to Perform Basic Operations 60 30 75kW Models ...
Page 193: ...Table of Functions 184 ...
Page 205: ...196 Troubleshooting ...
Page 228: ...Technical Specification 219 30 75kW Models 30 kW 3 Phase 37 45 kW 3 Phase ...
Page 230: ...Technical Specification 221 IP66 Models 0 4 4 0kW NP Non PDS type ...
Page 231: ...Technical Specification 222 0 4 4 0kW PDS type ...
Page 233: ...Technical Specification 224 5 5 7 5kW NP Non PDS type ...
Page 235: ...Technical Specification 226 11 0 22 0kW NP Non PDS type ...
Page 259: ...250 ...
Page 261: ...252 ...
Page 263: ...254 ...