Lohberger Heiztechnik
GmbH
Operating Instructions
N29/HB/GB
page 48
Lohberger Heiztechnik GmbH, A-5020 Salzburg-Bergheim, Rechtes Salzachufer 40
Tel. 0662-450444-0, Fax-DW 9
Es gelten unsere aktuellen allgemeinen Geschäftsbedingungen. Irrtum, Druckfehler und technische Änderungen vorbehalten
WHAT TO DO?
Delete the message (see point 8). Heating process can continue, but the customer service has to be
contacted immediately.
ERROR 33 currently not available!
ERROR 34 "OVERHEATED DO NOT OPEN ! Please wait..."
During log operation, the boiler temp. has exceeded 84°C; buffer and heating were not able to
accumulate more heat very probably.
WHAT TO DO?
Do not open doors, let boiler cool down! Insert less wood next time.
ERROR 35 "Outdoorprobe DISTURBED!"
This ERROR report displays a technical failure of the installation only qualified personal can fix!
Displayed if the outdoor probe signal is either over or under the normal range (larger than +80°C or
smaller than -45°C).
The mistake can lie with the probe itself (e.g. moisture intrusions) or with cable, clamps, or plugs.
WHAT TO DO?
Delete the message (see point 8). The system continues with a default value of 0°C if outddor
probe is defective. Contact qualified person as soon as possible.
ERROR 36 „Heatm.-Flowprobe DISTURBED !“
This ERROR report displays a technical failure of the installation only qualified personal can fix!
Displayed if the signal of the specified probe is either over or under the normal range (larger than
+130°C or smaller than -30°C).
The mistake can lie with the probe itself (e.g. moisture intrusions) or with cable, clamps, or plugs.
WHAT TO DO?
Delete the message. If displayed repeatedly, please contact your customer service.
ERROR 37 "Heat.circ1 flow-probe DISTURBED!"
This ERROR report displays a technical failure of the installation only qualified personal can fix!
Displayed if the heating circuit 1 flow-probe signal is either far over or under the normal range
(larger than +130°C or smaller than -30°C).
The mistake can lie with the probe itself (e.g. moisture intrusions) or with cable, clamps, or plugs.
WHAT TO DO?
Delete the message (see point 8). The affected heating circuit cannot continue operation with
defective probe, contact a qualified person.
ERROR 38 "Boiler return probe DISTURBED!"
This ERROR report displays a technical failure of the installation only qualified personal can fix!
Displayed if the return mixer has been activated (set to "ON) in the basic settings menu and the
boiler return probe signal is either far over or under the normal range (larger than +130°C or
smaller than -30°C).
The mistake can lie with the probe itself (e.g. moisture intrusions) or with cable, clamps, or plugs.
WHAT TO DO?
Delete the message (see point 8). The affected heating circuit cannot continue operation with
defective probe; contact a qualified person.
ERROR 39 "Heat.circ2 flow-probe DISTURBED!"
This ERROR report displays a technical failure of the installation only qualified personal can fix!
Displayed if the heating circuit 1 flow-probe signal is either far over or under the normal range
(larger than +130°C or smaller than -30°C).
The mistake can lie with the probe itself (e.g. moisture intrusions) or with cable, clamps, or plugs.
WHAT TO DO?
Delete the message (see point 8). The affected heating circuit cannot continue operation with
defective probe; contact a qualified person
ERROR 40 "Boiler Return- temperature too low!"