Lohberger Heiztechnik
GmbH
Operating Instructions
N29/HB/GB
page 19
Lohberger Heiztechnik GmbH, A-5020 Salzburg-Bergheim, Rechtes Salzachufer 40
Tel. 0662-450444-0, Fax-DW 9
Es gelten unsere aktuellen allgemeinen Geschäftsbedingungen. Irrtum, Druckfehler und technische Änderungen vorbehalten
Adjust Dom.Water temperatures
Loading Stop 55°C:
This value is adjustable! The domestic hot water is heated at every
loading process to that value.
Loading Start 45°C:
This value is adjustable! If the domestic hot water temperature falls
below this value during "high temperature" (see "Dom.Water Monitor"),
the loading process starts.
Loading Start 35°C:
This value is adjustable! If the domestic hot water temperature falls
below this value during "low temperature" (see "Dom.Water Monitor"),
the loading process starts.
Le (legionella killing):
If requested, here the so-called legionella function can be activated. If
"YES" is selected, the word "Day" is displayed.
Day:
Via this field, the day can be selected on which the legionella killing
should take place (see section "Menu map"). Additionally, the legionella
killing temperature can be set.
Timeprog:
Via this field you access the frame "Dom.Water Timeprog".
Domestic hot water legionella function
Day:
This value is adjustable! Setting of the day on which the temperature is
heated further up in order to kill possibly existing legionella bacteria.
Heating up to 65°C:
This value is adjustable!
NOTICE: Below 65°C the killing of the bacteria cannot be ensured!