Dom.Water timeprog:
Setup for "High temperature" timeprog:
The time values "from" and "to" are adjustable!
If the operation mode "Auto High/Low" in the frame "Dom.Water Monitor" has been selected, the
Loading start temperature (of the dom. Water cylinder) at this frame will be changed automatically once
the system time is inside the time slot of the Timeprog setup there.
If the numbers are set as in the picture, the following functions will be executed:
6.00 to 8.00 o'clock = Loading start high
8.00 to 19.00 o'clock = Loading start low
19.00 to 21.00 o'clock = Loading start high
21.00 to 0.00 o'clock and 0.00 to 6.00 o'clock = Loading start low
If only one time slot is needed, the values "from" and "to" in the 2nd line should be set to 0 or to the
same number, e.g. 19.00 to 19.00 o'clock.