7.3
Holidays / Absent:
Bild 1
Bild 2
Bild 3
On this menu screen a preselection can be done, to run heating as low as possible for a few days
(or weeks) to save energy if you go on holiday for example.
In this case, the date and time of the "holiday mode" can be entered in advance.
By specifying the duration (in days) the system can boot the heating in time for return from the
holiday and automatically bring the apartment as well as the dom. water to "operating
temperature".
On screen 2 the holiday mode has been "pre-set":
Starting on February 15 at 7 am, duration 5 days, the rooms are heated to 15 ° C, the hot water is
only heated when the temperature falls below the frost protection threshold (6 ° C). On February
20, at 7 am "holiday mode" ends and the heating is running again with the "usual" settings.
On screen 3 is indicated, which heating circuits are scheduled to start in the "holiday mode"
(heating circuit 1-6 or dom.water 1-3, only those circuits are displayed that are available in the
system).
On the right screen heating circuit 1 and 2 as well as the dom. water 1 was selected for the "holiday
mode".
NOTICE:
So that the rooms and the dom. water are at "operating temperature" upon return, the duration
should be set that the heating starts regular heating one day prior to returning from holiday.