Summary of Contents for HotZone Patio Heater

Page 1: ...n com www schaeferfan com High Output Infrared Heater 1500 3000 Watt INSTALLATION OPERATION INSTRUCTIONS 3019762 HotZone Portable Heater HotZone Wall Mount Heater HotZone Patio Heater HotZone Universal Fixed Mount Heater HOTZONE HEATERS MUST BE INSTALLED BY A LICENSED ELECTRICIAN ...

Page 2: ...er as a kind of floodlight and place it so as to cover your target area with enough heat The temperature increase resulting from the heater shining on a target depends on the power of the heater the distance from the heater to the target and how close the target is to the center of the spot DO NOT allow the heater to be aimed at a wall or any other combustible material The heater unit with fixed m...

Page 3: ... to properly grounded outlet only The heater should always be connected to a grounded circuit If a GFCI socket is not available GFCI adapters can be purchased locally Heater must be installed according to NEC and all local electrical codes Be sure the electrical supply is adequate for the heater voltage amps phase while allowing for line losses Use supply wires suitable for 90 C 10 Do not insert o...

Page 4: ...e assembly and allow the heater to be aimed as desired Typically the assembly should be in the middle of the back of the heater for downward facing ceiling mounting and toward the bottom and forward on the heater for downward through horizontal facing wall mounting see page 5 Be sure you are supplying the correct voltage to the heater allowing for line losses The heater s voltage requirements are ...

Page 5: ... Save all hardware for re use 1 Remove the two cap screws from the back of the heater which are holding the louvered element tray in place 2 Slide the element tray out of the heater Pull the high temperature element wires through the hole in the angle adjustment assembly to free the element 3 Remove the two allen screws that attach one end of the curved mounting plate to the heater 4 Remove the tw...

Page 6: ...range white and heats up very quickly The heater is receiving too much power and will burn out very quickly if it is not turned off Is the heater wired correctly for its element type Is the element damaged A short circuit between adjacent coils will cause some coils to go dark and some coils to overheat Damaged elements cannot be repaired and must be replaced MAINTENANCE The heater body can be was...

Page 7: ...500 1 2 A 120 7503 HZRE15208C HZS15208 1500 1 2 A 208 7504 HZRE15240C HZS15240 1500 1 2 A 240 7505 HZRE15277C HZS15277 1500 1 2 A 277 75301 HZRE30120 240C HZS30120 240 3000 2 3 B 120 B 240 75302 HZRE30208C HZS30208 3000 2 3 B 208 75303 HZRE30208YC HZS30208Y 3000 3 4 C 208 1 75304 HZRE30208DC HZS30208D 3000 3 3 D 208 75305 HZRE30240 480C HZS30240 480 3000 2 3 B 240 B 480 75309 HZRE30480C HZS30480 3...

Page 8: ...ion and or replacement of the heater element 1 Turn off power supply to the heater 2 Carefully remove the heater from the mount and disconnect the power supply The original white high temperature lead wires should be coming out through the mounting stub Figure 6 Be sure to save all hardware for re use 3 Place the heater on a level flat surface Be careful not to bend the lens lay the heater on a so...

Page 9: ...ure lead wires using the hardware that was removed from the used element Follow the appropriate wiring schematic on page 7 Figure 9 12 Carefully slide the element frame back into the heater The lead wires must be carefully pulled back through the mounting stub as the element is slid into place leaving them loose in the heater housing can cause them to overheat Figure 6 13 Replace the two allen scr...

Page 10: ...s to reverse the angle adjustment assembly before continuing 3 Thread the lead wires from the heater through the appropriate tube provided choose the 8 tube for ceiling mount 4 tube for wall mount and then through the stub in the cover plate 4 Secure the tube to the heater stub with a trilobal screw provided Secure the tube to the cover plate stub with the remaining trilobal screw 5 Recruit an ass...

Page 11: ...ropriate or regular maintenance of the product b Loss of time inconvenience loss of use of the product or other consequential or incidental damages c Parts that need replacement due to normal wear and tear d Superficial or cosmetic rust or corrosion e Any product whose name plate has been removed Products with warranty periods that differ from the standard 2 year warranty are as follows Poly Housi...

Page 12: ...800 779 3267 www schaeferfan com 2010 Schaefer Ventilation Equipment 11 17 10 ...