Lohberger Heiztechnik
GmbH
Operating Instructions
N29/HB/GB
page 39
Lohberger Heiztechnik GmbH, A-5020 Salzburg-Bergheim, Rechtes Salzachufer 40
Tel. 0662-450444-0, Fax-DW 9
Es gelten unsere aktuellen allgemeinen Geschäftsbedingungen. Irrtum, Druckfehler und technische Änderungen vorbehalten
8
"TC 3 Report System" – display during operation – Info / Notice /
Question / Error reports
The "TC3 Report System" displays 4 different report types on display:
Information to increase user's understanding of several processes in
boiler or heating. For better recognition, every INFO has its number,
e.g. "INFO 12 – Door open!". Each Info can be deleted by pushing
the button:
1. INFO xy =
Delete with button
or
Displayed if they are recalled via the text "Info!" or the symbol
2. NOTICE =
Deleted via button
or
In certain stati a question is posed after a user action, e.g. closing
the door: "Ash-trays empty?" To answer it, follow the instructions on
the display.
3. QUESTION =
In this case, push the button
if the ash-trays had been emptied
and button
if not.
An error is displayed if a status occurred that infringes or prevents
the heating operation, e.g. "Error 28 – check storage room". For
better recognition, every ERROR has its own number, e.g. "ERROR
12 – STB triggered–Overheated!". Additionally the display light
flashes every second.
4. ERROR xy =
Push buttons
and
alternatingly to delete or display
further error reports (if available).
8.1
List of INFO reports
INFO 1: "The boiler was overheated! To many logs filled"“ – not happening with PNA
Displayed after boiler overheated in log operation (i.e. boiler temperature exceeded 84°C). This
happens if wood is refilled although buffer reservoir was too warm.
WHAT TO DO? Delete the report (see point 8), measure the amount of wood better the next time
(fill in less).
INFO 2: "Burner activated because of Log self-ignition!" - not for PNA
Displayed if the burner switch is set to "OFF" and the control detects igniting wood in this status.
WHAT TO DO? Delete the report (see point 8), boiler runs in log operation until all wood is
consumed. During the consumption the burner switch flashes "OFF".
If you want the burner to switch on again automatically, the burner switch has to be set to "ON".