Lohberger Heiztechnik
GmbH
Operating Instructions
N29/HB/GB
page 12
Lohberger Heiztechnik GmbH, A-5020 Salzburg-Bergheim, Rechtes Salzachufer 40
Tel. 0662-450444-0, Fax-DW 9
Es gelten unsere aktuellen allgemeinen Geschäftsbedingungen. Irrtum, Druckfehler und technische Änderungen vorbehalten
7.3.10
Current burner operation mode::
Here, the current operation mode of the burner is displayed:
Pellet = the boiler is in operation mode "pellet"
7.3.11
Burner activity:
Here, the activitie is displayed that is executed at the moment. The following terms can be displayed:
////\\\\ = No activity (burner stopped)
Ready =Burner switch ist set to ON. The burner starts as soon as the starting criteria are met
(buffer up, temperature low).
Starting = Burner starting (ignites and heats the combustion chamber)
Working = Burner running (in regular heating operation)
Stopping = Burner stopping (residual material in combustion chamber will still be consumed)
Locked = The burner is disabled via the remote control input.
Tilting = The pellet grate is being cleaned (tilted) – distinct rattling noise audible.
2ndBoiler = On the Basicsettings-Menu the function “2
nd
boiler” is set to ON.
The system has activated the 2
nd
. Boiler.
"ERROR.STL!" =The safety temperature limiter (STL) has tripped. The error message is deleted. As
the boiler can not go into operation in this state, "ERROR.STL!" is displayed. To repair, see Error No
12
7.3.12
Combustion chamber temperature
Here, the current combustion chamber temperature is displayed.
During operation with pellets, this value ranges between 200 and 500°C (the longer the operating
time, the higher the temperature).
7.3.13
MENU:
By pushing the button "Next", you get into the main menu.
From here, all users or heating specialists settings can be changed, as well as retrieve temperatures,
operational stati, meter readings etc.