97
WWW.LCMETER.COM
LCI40
Series IOM
8 teChniCal data
Display And User Interface
Graphic Display
LC display, backlit white.
Size: 128 x 64 pixels, corresponds to 59 x 31 mm = 2.32” x 1.22”
Display turnable in 90° steps.
Ambient temperatures below -13°F / -25°C may affect the readability of the
display.
Operating Elements
4 mechanical and 4 optical keys for operator control of the signal converter
without opening the housing.
Infrared interface for reading and writing all parameters with IR interface (option)
without opening the housing.
Remote Operation
PACTwareTM (incl. Device Type Manager (DTM))
AMS® from Emerson Process
PDM® from Siemens
All DTMs and drivers are available free of charge from the manufacturer’s website.
Display Functions
Operating Menu
Setting the parameters using 2 measuring pages, 1 status page, 1 graphic page
(measured values and graphics are freely adjustable)
Language Display Texts (As
Language Package)
Standard: English, French, German, Dutch, Portuguese, Swedish, Spanish, Italian
Measurement Functions
Units: US and Metric units selectable as desired from lists for volume/mass flow
and counting, velocity, temperature, pressure
Measured values: Mass flow, total mass, temperature, density, volume flow, total
volume, velocity, flow direction (not displayed unit – but available via outputs),
BRIX,
Baume, NaOH, Plato, API, mass concentration, volume concentration
Diagnostic Functions
Standards: VDI / WIB 2650 and NE 107
Status messages:: Output of status messages optional via display, current and/or
status output, or bus interface
Sensor diagnosis: Sensor values, drive level, measuring tube frequency, 2 phase
signal, drive coil impedance, insulation fault, circuit interruption, exceeding the
maximum flow, process temperature
Self-diagnosing sensor electronics: Electronics temperature, input gains, driver
amplifier
Signal converter and inputs/outputs: Data bus monitoring, current output
connections, electronics temperature, voltage drop, parameter and data integrity
8.2 technical data