LCI40
Series IOM
3.1 General notes on installation
3. inStallation
information
Inspect the cartons carefully
for damages or signs of rough
handling. Report damage to the
carrier and to the local office of the
manufacturer.
information
Do a check of the packing list to
make sure that you have all the
elements given in the order.
information
The following precautions must be taken to ensure reliable installation.
• Make sure that there is adequate space to the sides.
• Protect the signal converter from direct sunlight and install a sun shade if necessary.
• Signal converters installed in control cabinets require adequate cooling, e.g. by fan or heat
exchanger.
• Do not expose the signal converter to intense vibrations. The measuring devices are tested for
a vibration level in accordance with IEC 68-2-64.
information
Look at the device nameplate to
ensure that the device is delivered
according to your order.
Check for the correct supply
voltage printed on the nameplate.
3.2 Storage
•
Store the device in a dry, dust-free location.
•
Avoid continuous direct sunlight.
•
Store the device in its original packing.
•
Storage temperature: -58°F to +158°F / -50°C to +70°C
3.3 transport
Signal Converter
•
No special requirements.
Compact version
•
Do not lift the device by the signal converter housing.
•
Do not use lifting chains.
•
To transport flange devices, use lifting straps. Wrap
these around both process connections.
3.4 installation Specifications