83
WWW.LCMETER.COM
LCI40
Series IOM
6 oPeration
Error Type Event Group
Single Event
Description
Actions to Eliminate
the Event
C
C Configuration
Sensor in Stop Mode
The device is in stop mode. No flow
measurement is being performed.
All flowrelated values displayed are
substitute values. The measuring tube is
not vibrating
Switch to measuring
mode for normal
operation.
Sensor in Standby
Mode
The device is in standby mode. No
flow measurement is being performed.
All flow-related values displayed are
substitute values. The measuring tube
continues to vibrate.
Sensor Simulation
Active
Simulation of mass flow, volume flow,
density or temperature
Switch off measured
value simulation.
Sensor Starting Up
The sensor is in start-up mode. This is
a normal state following a switch from
stop mode to measuring mode. The error
message “Sensor: Startup” becomes
active when this state goes on too long
or is unexpected.
Fieldbus Sim. Active
The simulation function in the Foundation
Fieldbus module is active and being
used.
Check Fieldbus settings.
PROFIBUS Sim/Man
Active
The simulation function in the PROFIBUS
module isactive and being used.
Check PROFIBUS
settings.
Totalizer 1 FB4 Sim.
Active
The simulation function in the PROFIBUS
module is active and being used.
Switch off simulation.
Totalizer 2 FB5 Sim.
Active
Totalizer 3 FB6 Sim.
Active
Totalizer 1 FB4 Man.
Active
The manual mode in the PROFIBUS
module is active.
Switch of manual mode.
Totalizer 2 FB5 Man.
Active
Totalizer 3 FB6 Man.
Active
IO A Simulation Active
IO A simulation is active.
Switch off simulation.
IO B Simulation Active
IO B simulation is active.
IO C Simulation Active
IO C simulation is active.
IO D Simulation Active
IO D simulation is active.
C
C Process
S
S Sensor
Temp. Or Strain Res.
Def.
The resistance network for temperature
and strain measurement is operated
outside of specifications and is possibly
faulty. The measured values for flow
and density remain valid however
the accuracy is undetermined. The
temperature measurement has failed.
Check connection
between measuring
sensor and signal
converter (remote
version) or replace
measuring sensor.
6.6 Status Messages and diagnostic information