29
WWW.LCMETER.COM
LCI40
Series IOM
Status output / limit Switch Passive, basic
i/os
•
U
ext
≤
32 VDC
•
I
≤
100 mA
•
R
L
, max = 47 k
Ω
R
L
, min = (U
ext
- U0) / I
max
•
Open:
I
≤
0.05 mA at U
ext
= 32 VDC
•
Closed:
U
0
, max = 0.2 V at I
≤
10 mA
U
0
, max = 2 V at I
≤
100 mA
•
The output is open when the device is de-energized.
•
X stands for the connection terminals B, C or D. The
functions of the connection terminals depend on the
settings refered to in Function tables on page 68.
Control input Passive, basic i/os
•
8 V
≤
Uext
≤
32 VDC
•
I
max
= 6.5 mA at U
ext
≤
24 VDC
I
max
= 8.2 mA at U
ext
≤
32 VDC
•
Switching point for identifying “contact open or
closed”:
Contact open (off): U0
≤
2.5 V with I
nom
= 0.4 mA
Contact closed (on): U0
≥
8 V with Inom = 2.8 mA
•
Can also be set as a status output; for the electrical
connection refer to status output connection diagram.
4. eleCtriCal ConneCtionS
4.10.3 basic inputs/outputs
4.10 description of the inputs and outputs
information
Compact and field housing
versions: Shield connected via
the cable terminals in the terminal
compartment.
Any connection polarity.
Status Output / Limit Switch Passive S
p
Control Input Passive C
p
1. Signal