Chapter 4 Performance specification
4-31
Remark
[Note1] TX LED of module flashes in a cycle of 1 second until modem is completely initialized.
If modem is initialized normally, TX LED and RX LED flash almost simultaneously indicating that
normal response of modem to initializing request of modem is performed. In this case, TX/RX LEDs
are no more flashing.
6) The case in which the initializing
described in (9) is completed normally indicates that modem and Cnet I/F
module are normally standing by with the following LED status kept until communication starts via
telephoning from the other PC or communication devices.
LED status in stand-by mode
G4L-CUEA
RS-232C
RS-422
RUN/BPS
TX/BPS
RX/BPS
ACK/DATA
NAK/PARITY
ERR/EVEN-ODD
MODEM/STOP
SYS-RUN
RUN/BPS
TX/BPS
RX/BPS
ACK/DATA
NAK/PARITY
ERR/EVEN-ODD
RS-485/STOP
SYS-ERR
7) After modem is initialized normally, modem and Cnet I/F module in stand-by status wait for RING signal until
received from the other modem.
8) If telephoned by the other modem prior to modem initializing, the module doesn’t respond out of normal
communication.
4.4.2.4 Answering to telephone and modem communication
If modem in local connection is initialized normally, communication with PLC is available by telephoning via the other
modem. However, this module supports not telephoning via Cnet but only answering function to telephone. If in the
state of on-line connection by telephoning, data communication in long distance is allowed via modem and the on-
line state is maintained as it is until the telephone is hung up by the other station compulsorily or by communication
error. LED display of Cnet I/F module in normal communication status is described as follows.
RUN/BPS : always ‘ON’
MODEM/STOP : always ‘ON’
SYS-RUN : dimly ‘ON’