Troubleshooting Guide
- 71 -
Copyright ©2013 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
1. Power cable or transmission cable is not
connected
2. Defect of outside Main fuse/Noise Filter
3. Defect of outside Main / inverter PCB
Error
No.
Error Type
Error Point
Main Reasons
Main controller of outside
unit of outside unit can’t
receive signal from
inverter controller
Transmission error between
(Inverter PCB
➔
Main PCB)
52*
■
Error diagnosis and countermeasure flow chart
Transmission connector & LED in MAIN PCB
Transmission connector & LED in inverter compressor PCB
Is transmission
LED (Yellow) of inverter
compressor
PCB on?
Yes
No
Is noise filter or fuse
normal?
Replace noise filter or fuse
No
Replace inverter compressor PCB
Is transmission cable
connected correctly?
Yes
No
Re-connect transmission cable
Is MAIN PCB normal?
Yes
No
Replace MAIN PCB
Replace inverter compressor PCB
* The method of checking MAIN PCB and inverter compressor PCB (If normal, transmission LED blinks)