Test Run
3.2 Dip switch setting
3.2.1 Location of setting switch
3.2.2 Dip switch setting
1. Set the dip switch and turn on the power of the outside unit to check whether the set value is correctly entered in
the 7-segment.
2. This function is shown for only 2seconds after the power is connected.
■
Check outside unit setting
• The number on the 7-segment is displayed in order after the power is connected.
• This number represents the setting condition.
■
Mode code
If the applicable dip switch is not set correctly,
the product may not operate properly.
CAUTION
SW01B SW02B
7-segment
SW01B
1
2
3
4
5
6
7
ON
SW02B
1
2
3
4
5
6
7
ON
Model Code
Unit(HP)
Powersupply
Ref.
120
4
121
5
1Ø, 208/230V
R410A
122
6
Order Number
Item
1
-
Model code
2
-
Total capacity in horsepower
3
2
Heat Pump
4
25
Normal mode display (If the dip switch is set incorrectly, it is not displayed.)
5
136
Model type (Water Mini)