
- 30 -
Copyright ©2013 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Test Run
The phenomena from main component failure
When system fault occurs, the error code is displayed at indoor unit display or remote control display, the trou-
ble shooting guide is in the service manual
• When CH05/53/11 ERROR occurs, check if auto-addressing has done and communication wiring is ok.
Compressor
Outside
EEV
Not operating
Stop during running
Abnormal noise
during running
Heating failure, fre-
quent defrosting
No operating sound
at applying power
Heating failure,
frozen outside heat
exchanger part
Low pressure error
or discharge temper-
ature error
Motor insulation broken
Strainer clogged
Oil leakage
Motor insulation failure
R-S-T misconnection
Bad connector contact
Coil failure
EEV clogged
EEV clogged
Check resistance between terminals and
chassis
Change strainer
Check oil amount after opening oil port
Check resistance between terminals and
chassis
Check compressor R-S-T connection
Check connector
Check resistance between terminals
Service necessary
Service necessary
Component
Phenomenon
Cause
Check method and Trouble shooting
2. How to cope with Test Run abnormality
Summary of Contents for ARWN038GA2
Page 81: ...P NO MFL67101202 APRIL 2013 ...