8400 motec | Software Manual
Parameter reference
Parameter list | C00909
290
L
Firmware
≤
02.00 - DMS 2.1 EN - 03/2011
C00909
C00910
C00971
C00972
Parameter | Name:
C00909 | Speed limitation
Data type: INTEGER_16
Index: 23666
d
= 5C72
h
Maximum positive/negative speed for all operating modes
Setting range
(min. value | unit | max. value)
0.0
%
175.0
Subcodes
Lenze setting
Info
C00909/1
120.0 %
Max. pos. speed
C00909/2
120.0 %
Max. neg. speed
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 100
Parameter | Name:
C00910 | Frequency limitation
Data type: UNSIGNED_16
Index: 23665
d
= 5C71
h
Maximum positive/negative output frequency for all operating modes
Setting range
(min. value | unit | max. value)
0
Hz
300
Subcodes
Lenze setting
Info
C00910/1
300 Hz
Max. pos. output frequency
C00910/2
300 Hz
Max. neg. output frequency
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C00971 | VFC: Limitation V/f encoder
Data type: UNSIGNED_16
Index: 23604
d
= 5C34
h
From version 02.00.00
Limitation of the output frequency of the slip regulator and limitation of the fed-in stator frequency for the V/f
control (
)
Setting range
(min. value | unit | max. value)
0.00
Hz
100.00
Subcodes
Lenze setting
Info
C00971/1
10.00 Hz
Maximum output value or correcting value of the slip
regulator
• The slip controller output is limited in motor and
generator mode to value set here.
• It is recommended to provide the 1 - 3-fold slip
frequency of the motor as limiting value.
C00971/2
100.00 Hz
Maximum frequency deviation between the mechanical
rotational frequency (speed) measured via the encoder
(speed) and the fed-in stator frequency.
• A limitation can prevent an overcurrent interruption
if e.g. a fixed limit stop is approached.
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 100
Parameter | Name:
C00972 | VFC: Vp V/f +encoder
Data type: UNSIGNED_16
Index: 23603
d
= 5C33
h
From version 02.00.00
Proportional gain of the slip regulator for V/f control (
)
• The gain must be selected as a function of the drive system and the encoder resolution (range of 0.005 ... 5).
• High gains assume high numbers of increments.
Setting range
(min. value | unit | max. value)
Lenze setting
0.000
Hz/Hz
64.000
0.100 Hz/Hz
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
;
MOT
Scaling factor: 1000