8400 motec | Software Manual
Function library
L_MPot_1
316
L
Firmware
≤
02.00 - DMS 2.1 EN - 03/2011
12.1.1
Activate & control motor potentiometer
When
bInAct
is set to FALSE, the motor potentiometer is activated.
The currently active function depends on the current output signal
nOut_a
, the limit
values set and the control signals at
bUp
and
bDown
.
When the
nOut_a
output signal is outside the limits set, the output signal runs to the
next limit with the Ti times set. This process is independent of the control signals at
bUp
and
bDown
.
When the
nOut_a
output signal is inside the limits set, the output signal changes
according to the control signals at
bUp
and
bDown
.
[12-1] Example: Control of the motor potentiometer
Use of the motor potentiometer
0 No
(Lenze setting)
The motor potentiometer is not used.
• The analog value applied to the
nIn_a
input is looped through
without any changes to the
nOut_a
output.
1 Yes
The motor potentiometer is used.
• The analog value applied at the
nIn_a
input is led via the motor
potentiometer and provided at
the
nOut_a
output.
Parameter
Possible settings
Info
nOut
_a
t
t
T
R
U
E
F
A
L
SE
bUp
t
T
R
U
E
F
A
L
SE
bD
own
nHi
gh
Limit
nLo
w
Limit
0
w
Tir
w
Tir
w
Tif
w
Tir
Summary of Contents for 8400 motec Series