Firmware
≤
02.00 - DMS 2.1 EN - 03/2011
L
327
8400 motec | Software Manual
Function library
L_PCTRL_1
0.0
s
999.9 Acceleration time for the ramp at the
PID output (should be set as steep as
possible)
• Lenze setting: 0.1 s
0.0
s
999.9 Deceleration time for the ramp at the
PID output
• Lenze setting: 0.1 s
(Pos. Maximum)
(Pos. Minimum)
(Neg. Minimum)
(Neg. Maximum)
0.0
%
199.9 Operating range
• Determination of the operating
range for the PID process
controller by limiting the input
signal
nSet_a
.
• Lenze setting: No limitation (-
199.9 % ... +199.9 %)
Operating mode
0 Off
(Lenze setting)
The input setpoint
nNSet_a
is output
without any changes at the output
nOut_a
.
1 Ad feedforward control
nNSet_a
and
nAct_a
are used as PID
input values. The arriving
nNSet_a
is
additively linked to the value output
by the PID element.
2 PID as setpoint generator.
nSet_a
and
nAct_a
are used as PID
input values. The input
nNSet_a
is
not considered.
3 PID setpoint from
nNSet_a
and
nAct_a
are used as PID
input values. The input
nSet_a
is not
considered.
0.0
s
999.9 Influence acceleration time
• Acceleration time T
ir
for the
influencing factor.
• Lenze setting: 5.0 s
0.0
s
999.9 Influence deceleration time
• Deceleration time T
if
for the
influencing factor.
• Lenze setting: 5.0 s
-199.9
%
+199.9 Display of PID output value
nPIDOut_a
Parameter
Possible settings
Info
Summary of Contents for 8400 motec Series