Firmware
≤
02.00 - DMS 2.1 EN - 03/2011
L
155
8400 motec | Software Manual
Drive application
Interface description
bCInh
BOOL
FALSE Enable controller: The controller switches to the "
device state, if no other source of a controller inhibit is active.
•
provides a bit coded representation of all active sources/
triggers of a controller inhibit.
TRUE Inhibit controller (controller inhibit): The controller switches to the
" device state.
bFailReset
BOOL
In the Lenze setting this input is connected to the digital input controller enable so
that a possibly existing error message is reset together with the controller enable (if
the cause for the fault is eliminated).
TRUE The current fault is reset, if the cause for the fault is eliminated.
• If the fault still exists, the error status remains unchanged.
bSetQuickstop
BOOL
Enable quick stop (QSP)
• Also see device command "
Activate/Deactivate quick stop
".
TRUE Activate quick stop
• Motor control is decoupled from the setpoint selection and,
within the deceleration time parameterised in
, the motor
is brought to a standstill (n
act
= 0).
• The motor is kept at a standstill during closed-loop operation.
• A pulse inhibit (CINH) is set if the auto-DCB function has been
activated via
.
FALSE Deactivate quick stop
• The quick stop is deactivated if no other source for the quick stop
is active.
•
displays a bit code of active sources/causes for the quick
stop.
bSetDCBrake
BOOL
Manual DC-injection braking (DCB)
• Detailed information on DC-injection braking is provided in the motor control
chapter, subchapter "
Note!
Holding braking is not possible when this braking mode is used!
Use the basic "
" function for controlling the holding brake with
a low rate of wear.
FALSE Deactivate DC-injection braking.
TRUE Activate DC-injection braking, i.e. the drive is brought to a standstill
by means of DC-injection braking.
• The braking effect stops when the rotor is at standstill.
• After the hold time (
) has expired, the controller sets the
pulse inhibit (CINH).
Fail-safe selection of the direction of rotation in connection with quick stop
• In control mode "Terminals 16", both inputs are connected to the digital terminals DI3 and DI4.
• For a detailed functional description see FB
.
bRLQCw
BOOL
Activate clockwise rotation (fail-safe)
FALSE Quick stop
TRUE Clockwise rotation
bRLQCcw
BOOL
Activate counter-clockwise rotation (fail-safe)
FALSE Quick stop
TRUE Counter-clockwise rotation