Firmware
≤
02.00 - DMS 2.1 EN - 03/2011
L
201
8400 motec | Software Manual
Diagnostics & error management
Monitoring
9.5.2
Setting the error response
When a monitoring function responds, the response set for this monitoring function
(Trouble, Fault, etc.) will be triggered.
For many monitoring functions the response can be individually parameterised via
parameters.
Tip!
" contains the error messages for which
Warning thresholds
Some of the monitoring functions are activated if a defined warning threshold has been
exceeded.
The corresponding preset threshold values can be changed via the following
parameters:
Parameter
Info
Lenze setting
Value Unit
Motor overload threshold (I²xt)
100 %
Device utilisat. threshold (Ixt)
100 %
Max. positive speed
120 %
Max. negative speed
120 %
Max. positive output frequency
300 Hz
Max. negative output frequency
300 Hz