Firmware
≤
02.00 - DMS 2.1 EN - 03/2011
L
319
8400 motec | Software Manual
Function library
L_NSet_1
Outputs
Parameter
Identifier
Data type
Value/meaning
nNOut_a
INT
Speed setpoint output signal
• Scaling: 16384
≡
100 %
wState
WORD
Bit-coded status word
• Bits that are not listed are reserved for future extensions.
Bit 0 No blocking zone active
Bit 1 Blocking zone 1 active
Bit 2 Blocking zone 2 active
Bit 3 Blocking zone 3 active
Bit 4 Jog in blocking zone
Bit 5 MaxLimit active
Bit 6 MinLimit active
Parameter
Possible settings
Info
0.0
s
999.9 Acceleration time T
ir
for the main
setpoint
• Lenze setting: 2.0 s
0.0
s
999.9 Deceleration time T
if
for the main
setpoint
• Lenze setting: 2.0 s
-199.9
%
199.9 Fixed setpoint 1 (JOG setpoint 1)
• Lenze setting: 40.0 %
-199.9
%
199.9 Fixed setpoint 2 (JOG setpoint 2)
• Lenze setting: 60.0 %
-199.9
%
199.9 Fixed setpoint 3 (JOG setpoint 3)
• Lenze setting: 80.0 %
Activates ramp rounding with PT1
behaviour for the main setpoint
• The corresponding S-ramp time
• Lenze setting: 0 (deactivated)
0 Off
1 PT1 behaviour
0.01
s
50.00 S-ramp time PT1
• Lenze setting: 20.00 s
0.0
%
199.9 Maximum limit values for the speed
blocking zones
• Selection of the maximum limit
values for the blocking zones in
which the speed must not be
constant.
• Lenze setting: 0.0 %
0.0
%
199.9 Minimum limit values for the speed
blocking zones
• Selection of the minimum limit
values for the blocking zones in
which the speed must not be
constant.
• Lenze setting: 0.0 %