8400 motec | Software Manual
Parameter reference
Parameter list | C01501
296
L
Firmware
≤
02.00 - DMS 2.1 EN - 03/2011
C01501
C01503
Parameter | Name:
C01501 | Resp. to communication error with MCI
Data type: UNSIGNED_8
Index: 23074
d
= 5A22
h
Configuration of monitoring modes for the communication unit
Selection list
0 No Reaction
1 Fault
4 WarningLocked
Subcodes
Lenze setting
Info
C01501/1
1: Fault
Resp. to MCI error 1
• Response to a communication error.
C01501/2
1: Fault
Resp. to MCI error 2
• Response to an incompatible communication unit.
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1
Parameter | Name:
C01503 | MCI timeout
Data type: UNSIGNED_16
Index: 23072
d
= 5A20
h
Setting range
(min. value | unit | max. value)
0
ms
1000
Subcodes
Lenze setting
Info
C01503/1
200 ms
MCI timeout
;
Read access
;
Write access
CINH
PLC STOP
No transfer
COM
MOT
Scaling factor: 1