8400 motec | Software Manual
Motor control (MCTRL)
V/f characteristic control - energy-saving (VFCplusEco)
78
L
Firmware
≤
02.00 - DMS 2.1 EN - 03/2011
5.6.1
Parameterisation dialog/signal flow
Proceed as follows to open the dialog for parameterising the motor control:
1. »Engineer« Go to the
Project view
and select the 8400 motec controller.
2. Go to
Workspace
and change to the
Application parameters
tab.
3. Select the motor control"11: VFCplusEco: V/f energy-saving" from the
Overview
dialog box in the
Motor control
11list field:
4. Click the
Motor control V/f Eco
button to change to the
Overview
Motor control
V/f
dialog box.
• This dialog level only shows a simplified signal flow with the most important
parameters.
• When you click the
>>More details
button in the left-most position, a signal
flow with more details/parameters is displayed.
Stop!
• For adjustment, observe the thermal performance of the connected
asynchronous motor at low output frequencies.
– Usually, standard asynchronous motors with insulation class B can be
operated for a short time with their rated current in the frequency range 0
Hz ... 25 Hz.
– Contact the motor manufacturer to get the exact setting values for the
max. permissible motor current of self-ventilated motors in the lower
speed range.
• The nameplate data of the motor (at least rated speed and rated frequency)
must be entered if, instead of a standard motor, an asynchronous motor is
used with the following values:
– rated frequency
≠
50 Hz (star) or
– rated frequency
≠
87 Hz (delta) or
– number of pole pairs
≠
2