8400 motec | Software Manual
Motor control (MCTRL)
V/f control (V encoder)
86
L
Firmware
≤
02.00 - DMS 2.1 EN - 03/2011
5.7
V/f control (V encoder)
This function extension is available from version 02.00.00!
The previously described V/f characteristic control (VFCplus) can be operated with a
feedback of speed. This bears the following advantages:
Stationary accuracy of speed
Low parameterisation effort compared to sensorless vector control (SLVC)
Improved dynamics compared to V/f characteristic control without feedback or to
sensorless vector control (SLVC).
Suitability for group drives
The descriptions in chapter "
V/f characteristic control (VFCplus)
the V/f control.
Note!
• The speed feedback mandatory for this motor control type can be fed in at the
digital input terminals (DI1/DI2) via an HTL encoder.
– In order that the HTL encoder can be evaluated correctly, the digital input
terminals (DI1/DI2) must be configured as frequency inputs.
DI1 and DI2 as frequency inputs
• Make sure that the maximum input frequency of 10 kHz is not exceeded
when the motor control with speed feedback is used.
• As the slip is calculated in the feedback V/f operation and injected through
the slip regulator, the slip compensation (
control.
Summary of Contents for 8400 motec Series
Page 375: ...L 375 ...