Attention:
To avoid component damage, connect the power cords last.
5. Update the server configuration.
• Download and install the latest device drivers:
http://datacentersupport.lenovo.com
.
• Update the system firmware. See
.
• Update the UEFI configuration.
• Reconfigure the disk arrays if you have installed or removed a hot-swap drive or a RAID adapter. See
the Lenovo XClarity Provisioning Manager User Guide, which is available for download at:
.
Note:
Make sure the latest version of ThinkSystem M.2 with Mirroring Enablement Kit Firmware is applied to
avoid virtual disk/array missing after system board replacement.
Hardware disassembling for chassis recycle
See this topic to learn how to comply with regulations before recycling the chassis.
Step 1. If applicable, remove the security bezel (see
“Remove the security bezel” on page 137
Step 2. Remove the power supply units (see
“Remove a hot-swap power supply unit” on page 124
).
Step 3. Remove the top covers (see
“Remove the top covers” on page 168
).
Step 4. Remove the air baffle (see
“Remove the air baffle” on page 43
).
Step 5. Remove the fan cage assembly (see
“Remove the fan cage assembly” on page 72
Step 6. Remove both PCIe riser assemblies (see
“Remove the PCIe riser assemblies and adapters” on
).
Step 7. Remove the M.2 boot adapter (see
“Remove the M.2 boot adapter and drives” on page 90
).
Step 8. Remove the trayless drive cage (see
“Remove the drive cage and trayless drives” on page 156
Step 9. Remove the power backplane (see
“Remove the power backplane” on page 120
Step 10. Remove the OCP adapter (see
“Remove the OCP Ethernet adapter” on page 95
).
Step 11. Remove the system board (see
“Remove the system board assembly” on page 149
).
Step 12. Remove the security bezel cable module (see
“Remove the security bezel cable module” on page
).
Step 13. Recycle the chassis in compliance with local regulations.
.
Hardware replacement procedures
175
Summary of Contents for 7D8T
Page 1: ...ThinkEdge SE450 Maintenance Manual Machine Types 7D8T ...
Page 8: ...vi ThinkEdge SE450 Maintenance Manual ...
Page 22: ...14 ThinkEdge SE450 Maintenance Manual ...
Page 45: ...Server components Figure 17 Server components Chapter 2 Server components 37 ...
Page 184: ...176 ThinkEdge SE450 Maintenance Manual ...
Page 206: ...198 ThinkEdge SE450 Maintenance Manual ...
Page 210: ...202 ThinkEdge SE450 Maintenance Manual ...
Page 217: ......
Page 218: ......