Figure 73. Installing the M.2 drives
Align the M.2 drives with the connectors.
Pivot the other end of the M.2 drives toward the backplane.
Slide the retaining clips forward to secure the drives to the backplane.
Step 3. Contain the cables between the guiding pin and the two cable clips as illustrated. Align the pointed
ends of the two triangles on the adapter and the power supply cage, and lower the bracket. Then,
slide the adapter backward slightly, and tighten the captive screw to secure the adapter.
Note:
To spare space for proper installation, make sure to contain the cables with the two cable
clips as illustrated before installing the adapter.
Figure 74. Installing the M.2 boot adapter
94
ThinkEdge SE450 Maintenance Manual