6: Networking
EMG™ Edge Management Gateway User Guide
75
Advanced Cellular Gateway Configuration
Fail-Over Cellular Gateway Firmware
Note:
The HSPA+ or Sierra fail-over device must be selected in order for you to be able
to update the firmware.
New Admin
Password/Retype
For the selected
Fail-over Device
, the administrator password can be changed on
the gateway. The password may have up to 64 characters.
To change the Admin Password, click the Change Admin Password checkbox and
enter the new password in the New Admin Password and Retype fields. Changing
the HSPA+ Admin password will save the password on the EMG for status and
configuration queries to the HSPA+ gateway. The password must match what is
stored on the HSPA+ gateway. Changing the Sierra Admin password will save the
password on the EMG for status and configuration queries to the Sierra gateway.
The new password will also be configured on the Sierra gateway. The Sierra
gateway login must be set as ‘user’.
Reboot Gateway
When Making
Changes (check
box)
Select this check box if you wish to reboot the selected fail-over device when
making changes.
Fail-Over Cellular
Gateway Status
(link)
Clicking the link opens the Fail-Over Cellular Gateway status window, showing
status and statistics about the fail-over gateway.
Click Back to Network Settings to return to the Network Settings page.
SIM Card PIN Lock
(check box)
For the HSPA+ and Sierra gateways, enable a lock so that the SIM card used by the
gateway cannot be used by anyone who does not have the PIN.
Pin # for SIM Card/
Retype
For the HSPA+ and Sierra gateways, the PIN number for the SIM card used by the
gateway. May have up to 8 characters.
SIM PUK/Retype
For the HSPA+ gateway, the SIM Personal Unblocking Key (PUK). May have up to
16 characters. The Sierra gateway does not have this feature.
SIM Username
For the HSPA+ gateway, enter the username for dial up to the cellular carrier, if
required. May have up to 64 characters. The Sierra gateway does not have this
feature.
SIM Password
For the HSPA+ gateway, enter the password for dial up to the cellular carrier, if
required. May have up to 64 characters. The Sierra gateway does not have this
feature.
Dial-up String
For the HSPA+ gateway, enter the modem string used for making a connection to
the carrier. May have up to 64 characters. The Sierra gateway does not have this
feature.
Roaming
For the HSPA+ gateway, enable or disable network roaming. The Sierra gateway
does not have this feature.
Update Firmware
(check box)
Select this option to update firmware on the HSPA+ gateway or the Sierra gateway.
The
Functional Firmware file
and the
Radio Firmware file
(required for the Sierra
gateway only) will be transferred to the EMG using the method selected by the
Load Firmware via
option. Once the file(s) have been transferred to the EMG, the
EMG will initiate the firmware update on the gateway.
Functional Firmware
Filename
Enter the name of the firmware filename exactly as it is represented.