3: Installation
EMG™ Edge Management Gateway User Guide
47
I/O Module Installation
The EMG module port configuration can be changed by adding or replacing I/O modules in the I/O
module bays.
Warning:
Install the I/O module on the front only of the EMG unit. Do not insert
any other module on the front of the EMG unit. Doing so may damage
the EMG unit and will void the warranty.
To install an I/O module:
1. Disconnect the power cord from the EMG unit and from the wall outlet. The EMG must be
powered off when installing or replacing the modules.
2. On the front of the EMG unit, locate the module bay where the module will be inserted.
3. Unscrew the existing module or faceplate from the module bay with your fingers and carefully
remove it from the module bay.
4. Insert the module into the module bay making sure the module sits completely and securely in
the housing.
5. The module will sit flush with the EMG chassis.
6. Tighten the screw on the module with your fingers. Be careful not to over tighten it.
7. To verify the new module is recognized, connect power to the EMG, wait for it to boot, and log