16: Command Reference
EMG™ Edge Management Gateway User Guide
369
Parameters
actiondelay <Action Delay>
actionrestart <Restart Delay>
bytethreshold <# of Characters>
emailsubj <Email Subject>
emailto <Email Address>
locallogging <enable|
disable
>
nfsdir <Logging Directory>
nfslogging <enable|
disable
>
nfsmaxfiles <Max # of Files>
nfsmaxsize <Size in Bytes>
poweraction <on|off|cycle>
powersupply <Managed Power Supply Name>
sendstring <String to Send|QUOTEDSTRING>
tokenaction <List of none,log,trap,email,string,power>
tokendatadetect <enable|disable>
tokenstring <Regex String>
tokentrigger <bytecnt|charstr>
usblogging <enable|
disable
>
usbmaxfiles <Max # of Files>
usbmaxsize <Size in Bytes>
usbport <U1|SD|INTSD>
sysloglogging <enable|
disable>
Description
Configures logging settings for one or more device ports.
Local logging must be enabled for a device port for the
locallog
commands to be executed. To
use the
set locallog clear
command, the user must have permission to clear port buffers
Chapter 13: User Authentication
.)
Example
set deviceport port 2-5,6,12,15-16 locallogging enable
show locallog
Syntax
show locallog <Device Port # or Name> [<parameters>]
Parameters: [bytes <Bytes To Display>]
[startbyte <Byte Index>]
Defaults: bytes=1000, startbyte=1
Description
Displays a specific number of bytes of data for a device port.
1
K is the default.