Calibration by Sample Weight
This is to calibrate the scale with the maximum precision.
This Calibration can be executed in two ways:
•
With a Sample Weight
.
This is the method which achieves the maximum precision.
Calibration will be ideal by using a Sample Weight at least
50% the Maximum Load of the mixing wagon.
•
With a Weight Calibrator
.
Before executing Calibration, bring the Calibrator selector
to “ZERO”. The value to be set with the Sample Weight is
that indicated in Table 1 in the column "Calibration Value".
After having set the value, move the selector of the
Calibrator to “CAL”., then press
OK
.
1.
To execute the Calibration, select the item “CAL. by SAMPLE
WEIGHT”, then press
u
.
The display shows the message “Do you want to execute the
Calibration?”.
2.
Press
OK
to confirm.
The display shows the following messages in succession
"Calibration in progress. Wait...", “Zero Scale executed
correctly.", "Enter the value of the Sample Weight.” and after
3 seconds the Sample Weight to be set.
3.
Press
u
to program the value.
The display shows the icon
.
4.
Enter the Sample Weight value, then press
OK
.
The display shows the message “Load the Sample Weight
and press OK.”.
5.
Load the Sample Weight onto the mixing wagon, then press
OK
.
The display shows the message "Calibration in progress.
Wait...” and at the end the message “Calibration executed
correctly.”.
Summary of Contents for I Feed Good L
Page 1: ... i FeedGood L Weighing System Technical Guide ...
Page 2: ... ...
Page 13: ...i FeedGood L Technical Guide 11 Connection diagram base version ...
Page 15: ...i FeedGood L Technical Guide 13 Connection diagram with wireless Remote Terminal ...
Page 128: ... ...
Page 129: ... ...
Page 130: ... ...