i
•
FeedGood
L
• Technical Guide
|
81
Relay Outputs Setting
This is for choosing which functions you want to associate to the
"Relay Output", “3-Relay Outputs” or “4-Relay Outputs” options.
Note
: the Preference is only displayed if the scale is supplied with
the "Relay Output", “3-Relay Outputs” or “4-Relay Outputs”
options.
Note
: for more information refer to the documentation attached to
"Relay Output", “3-Relay Outputs” or “4-Relay Outputs” options or
contact the Customer Service.
Display: RELAY OUT SET
Options:
No
, Lubrication, Knives, Lubrication/Knives, Keyboard
4-Keys.
Counterknives Parameters Setting
This is used to programme the parameters for automatic actuation
of the counterknives during the mixing wagon cutting cycle.
Note
: for more information refer to the documentation attached to
the “3-Relay Outputs”, “4-Relay Outputs” and “7-Power Outputs”
options or contact the Customer Service.
Note
: the “COB-ID#1” item only appears if “L-Link Port” or
“CAN-Bus Port” System Preferences have the “Label 5 or label 6”
option set.
Display: COUNTERKNIVES
Options:
•
MODE:
No,
Semi-automatic
, Automatic.
•
TIME IN(s):
1 … 600 (
20
).
•
TIME OUT(s):
1 … 600 (
20
).
•
PULSE ON(s):
1 … 60 (
10
).
•
PULSE OFF(s):
1 … 60 (
10
).
•
TOTAL TIME(min):
1 … 90 (
20
).
•
THRESHOLD (kg/lb):
0 … 99.999 (
0
).
•
DELAY(s):
0 … 300 (
0
).
•
COB-ID#1:
4-character alphanumeric (
18F
).
Summary of Contents for I Feed Good L
Page 1: ... i FeedGood L Weighing System Technical Guide ...
Page 2: ... ...
Page 13: ...i FeedGood L Technical Guide 11 Connection diagram base version ...
Page 15: ...i FeedGood L Technical Guide 13 Connection diagram with wireless Remote Terminal ...
Page 128: ... ...
Page 129: ... ...
Page 130: ... ...