Maintenance
In order to prevent malfunctioning or failures, it is recommended
to perform the following operations periodically:
•
Check that the external power supply system to the scale
works properly, also checking that the connection points
have no oxidization or humidity.
•
Check that the load cells have no dents. The possible
presence of rust on the load cell body does not endanger
its operation.
•
Check that all parts of the weighing system have no dents
or signs of burns.
•
Check that the loaded weight corresponds with the weight
displayed by the scale, loading a weight with a known
value on the mixing wagon.
•
Check clamping of all the screws on the parts making up
the weighing system.
•
Periodically clean the scale using a moist, soft and down-
free cloth. Never use sprays, abrasives, solvents or sharp
objects which can damage the case.
•
Before cleaning the mixing wagon with high pressure
water jets, disconnect the connection cables, remove the
scale from the mixing wagon and protect the connectors of
the connection cables from possible water infiltrations.
Also pay the utmost attention not to spray the load cells,
junction box, alarm devices and other accessories directly
with water.