Weight Hold Function
1.
If you must move the mixing wagon during execution, press
PAUSE
to activate the Weight Hold Function. The display
shows “
HOLD
” and the message “LOCKED WEIGHT”. After
having moved the mixing wagon, press
PAUSE
once again to
resume weighing operations.
How to replace an Ingredient/Clean-Up
If the material to be loaded finishes during execution, you can
replace it with another present in the Archive and thus continue
the weighing operations.
1.
Press
MENU
, select the item “REPLACE ELEMENT”, then
press
u
. The display shows the Ingredients/Clean-Ups stored
in the Archive.
2.
Select the Ingredient/Clean-Up and then press
u
. The scale
resumes the weighing operations proposing the
Ingredient/Clean-Up to be weighed and the remaining weight
to be loaded.
Maximum Load check
1.
If the "Maximum Load" Weighing Preference is programmed,
during weighing the scale checks that the programmed value
is not exceeded, otherwise the display shows “
ERR 21
”. For
further information, see “Annex C – Error Codes”.
Reload Function
1.
If the Reload Function is enabled and all the
Ingredients/Clean-Ups have been loaded completely, after
loading the last Ingredient/Clean-Up, the display shows the
message "Reload phase.", re-proposing the
Ingredients/Clean-Ups which were not weighed completely
and the remaining amount to be loaded.
Summary of Contents for I Feed Good L
Page 1: ... i FeedGood L Weighing System Technical Guide ...
Page 2: ... ...
Page 13: ...i FeedGood L Technical Guide 11 Connection diagram base version ...
Page 15: ...i FeedGood L Technical Guide 13 Connection diagram with wireless Remote Terminal ...
Page 128: ... ...
Page 129: ... ...
Page 130: ... ...