44
|
i
•
FeedGood
L
• Technical Guide
•
Mixing Timer
When the scale executes a Mixing Timer, the
display shows the icon and the countdown of the
programmed time.
At the end of the countdown, the display shows the
message “Countdown completed.” for 3 seconds
while the scale activates the Alarm Output twice.
After this, execution of the Recipe resumes by
displaying the next element.
Press
ESC
if you want to interrupt the countdown.
The display shows the message “Do you want to
cancel the countdown? Press OK to confirm or ESC
to cancel.”. If you press
OK
the display shows the
message “Countdown has been cancelled.” for 3
seconds, while the scale activates the Alarm Output
twice. After this, execution of the Recipe resumes by
displaying the next element.
3.
If during weighing operations you want to view the Total
Weight, press
NET/TOTAL
.
Prealarm Threshold
1.
When the weight displayed reaches 15% the programmed
value (see “Prealarm” Weighing Preference), the display
shows the icon flashing, while the scale activates the
Alarm Output intermittently. As weighing operations continue,
the Alarm Output activates more frequently.
Note
: during the Prealarm, the display shows the Name and
type of the next element.
Queue Time
1.
When the weight displayed is “0” or less, the Alarm Output
activates for 5 seconds (see “Queue Time” Weighing
Preference). If during the Queue Time the display shows a
negative value, it means that an amount of food equal to the
value displayed was weighed beyond the programmed value.
Note
: during the Queue Time the display shows the
countdown of the programmed time.
Summary of Contents for I Feed Good L
Page 1: ... i FeedGood L Weighing System Technical Guide ...
Page 2: ... ...
Page 13: ...i FeedGood L Technical Guide 11 Connection diagram base version ...
Page 15: ...i FeedGood L Technical Guide 13 Connection diagram with wireless Remote Terminal ...
Page 128: ... ...
Page 129: ... ...
Page 130: ... ...