Weight Display
This is for choosing how you want to show the weight in Recipes
Execution and in Target Weighing.
•
If you set "Down", the weight displayed starts from the
programmed value and the value decreases as you weigh.
•
If you set "Up", the weight displayed starts from "0" and
the value increases as you weigh.
Display: WEIGHT DISPLAY
Options:
Down
, Up.
Prealarm
This is to enable and program the threshold which when reached,
in Recipes Execution and in Target Weighing, activates the Alarm
Output.
Note
: to disable the Preference, set the "VALUE" field at "0".
The threshold can be intermittent or continuous.
•
If you program "Intermittent", the Alarm Output is
activated/deactivated with a frequency which increases
proportionally as the programmed weight approaches
100%.
•
If you program "Continuous", the Alarm Output is activated
continuously.
The threshold can be expressed in absolute value (kg/lb) or in
percentage respect to the programmed weight.
Display: PREALARM
Options:
•
OUTPUT TYPE:
Intermittent
and Continuous.
•
VALUE TYPE:
Percentage
, Absolute.
•
VALUE:
0 … 50 % (
15
).
0 … 999 kg/lb (
50
).