1AH
1-3-36
• Automatic exposure mode control
In automatic exposure mode, prescanning is carried out with the halogen lamp (HL) lit the
light intensity for EXP4 and the exposure intensity for copying is determined by the output
voltage of the AE sensor (AES). The light intensity for the halogen lamp for copying is
controlled with the NTC original and NPTC original scanner AE sensor voltage values
obtained by executing simulation 22 made to correspond to EXP4 and EXP7-2 for manual
exposure.
NTC
NPTC
Light intensity data
Manual exposure EXP7
Manual exposure EXP7-2
Manual exposure EXP4
AE sensor
input voltage
Figure 1-3-33
Automatic exposure control
Summary of Contents for DC-2060
Page 1: ...SERVICE MANUAL Published in Oct 99 841AH110 DC 2060 2560 DC 2060 2560...
Page 2: ...Service Manual DC 2050 2560...
Page 4: ......
Page 13: ...1AH MCE THEORY AND CONSTRUCTION SECTION I I Theory and Construction Section...
Page 14: ...1AH 1 1 Specifications 1 1 1 Specifications DC 2560 1 1 1 1 1 4 Specifications DC 2060 1 1 4...
Page 24: ......
Page 30: ...1AH 1 3 6 1 2 3 4 5 6 7 8 9 0 1 3 3 Drive system Figure 1 3 6 Drive system copier...
Page 82: ...1AH MCE ELECTRICAL SECTION II II Electrical Section...
Page 83: ...1AH 2 1 Electrical Parts Layout 2 1 1 Electrical parts layout 2 1 1...
Page 84: ......
Page 94: ......
Page 105: ......
Page 124: ...1AH MCE III Set Up and Adjustment Section III SET UP AND ADJUSTMENT SECTION...
Page 126: ......
Page 151: ......
Page 177: ...1AH This page is intentionally left blank...
Page 185: ...1AH This page is intentionally left blank...
Page 209: ......
Page 259: ...3 3 50 1AH Figure 3 3 59 Secondary mirror inclination adjustment screw Secondary mirror...
Page 351: ......
Page 357: ......