Chapter 5: Troubleshooting
Status signaling
112
01010 to
01019
Temperature too
low (critical)
Low ambient temperature
is causing the performance
of the terminal to be
degraded or halted.
Move the terminal to a
warmer location.
For information on
ambient temperature
limits, see the installation
manual.
01020 to
01029
Too low
temperature
warning
Low ambient temperature
is causing the performance
of the terminal to be
degraded or halted.
The terminal will assume
radio silence if the
problem is in the ACM
module of the antenna.
Move the terminal to a
warmer location.
For information on
ambient temperature
limits, see the installation
manual.
01110 to
01119
Temperature too
high (critical)
Terminal:
Critically high
temperature is causing the
terminal to shut down.
Antenna: Critically high
temperature is causing the
antenna to stop
transmission.
If possible, move the
failing unit to a cooler
location.
For information on
ambient temperature
limits, see the installation
manual.
Contact your dealer/
distributor if the problem
persists.
01120 to
01129
Too high
temperature
warning
High ambient temperature
is causing the performance
of the system to be
degraded or halted.
The bit rate is reduced.
Move the terminal to a
cooler location.
For information on
ambient temperature
limits, see the installation
manual.
01300 to
01309
No GPS fix
The GPS receiver has not
yet achieved position fix.
Make sure the view to the
GPS satellites is not
blocked.
Note that in some cases it
may take up to 10 minutes
to obtain GPS fix.
01400 to
01409
Satellite
signal lost
The TracPhone FB150 no
longer receives a signal
from the satellite.
Make sure the
TracPhone FB150 has a
clear view to the satellite.
ID
Event Text
Explanation
Remedy