Chapter 4: Using the web interface
Setting up the interfaces
84
Pin 4: Radio silence input.
Activation of this pin causes the system to assume radio silence, i.e. to stop all
transmission from the system. The terminal gracefully closes all open connections,
and deregisters from the BGAN network. No transmission is allowed until the pin is
deactivated. You can configure pin 4 to Active low or Active high.
• Active low (default): Connect pin 4 to ground (< 1.2 V DC) when it should be
activated.
• Active high: Connect pin 4 to ground (< 1.2 V DC). When it should be activated,
disconnect it from ground.
Pin 5/8: Ignition input.
The ignition function can be used to turn on/off the terminal by means of an
external signal. The external signal that triggers the ignition function can be either
positive DC voltage or ground. The ignition function uses pin 5 together with pin 8
(DC in). Connect the appropriate pin to the ignition switch as follows:
• Active high (default): Connect pin 5 permanently to ground. Connect pin 8 to
positive DC voltage (10.5-32 V DC) when the ignition is on. To switch off,
disconnect pin 8 from the positive DC voltage.
• Active low: Connect pin 8 permanently to positive DC voltage (10.5-32 V DC).
Connect pin 5 to ground (< 1.2 V DC) when the ignition is on. To switch off,
disconnect pin 5 from ground.
Pin 6: Ground.
(Non-configurable) Pin 6 can be used as an external connection to ground. Pin 6 is
connected to ground inside the terminal.
Pin 7: DC output.
(Non-configurable) Pin 7 can be used as a DC output. The voltage on pin 7 is 9-15 V
and the output can supply up to 50 mA. Pin 7 can be used as power supply to a
relay, ringer or similar.