ELECTRICAL SYSTEM
L3560, L4060, L4760, L5060, L5460, L6060, WSM
9-S8
9Y1210824ELS0151US0
ERROR No. 90
HST-F SOLENOID NG
Proportional valve for
forward is in trouble
• Output voltage of proportional
valve terminal or return current
is out of specification
• Wiring for proportional valve is
disconnected or short-circuited
• Proportional valve failure
Travel motion is possible on
the backward side only
–
Check the connector of
proportional
Check the proportional valve
by Test mode (Mode A)
Check the proportional valve
resistance at valve or main
ECU connector
Check the ground cable
Replace the proportional valve
ERROR No. 91
HST-R SOLENOID NG
Proportional valve for
reverse is in trouble
Travel motion is possible on
the forward side only
–
Check the connector of
proportional
Check the proportional valve
by Test mode (Mode A)
Check the proportional valve
resistance at valve or main
ECU connector
Check the ground cable
Replace the proportional valve
ERROR No. 92
Hi-Lo SOLENOID NG
Hi-Lo solenoid shift is in
trouble
• Hi-Lo solenoid output terminals
voltage is out of specification
• Hi-Lo solenoid broken or
short-circuited
• Wiring for Hi-Lo solenoid valve
is disconnected or
short-circuited
Travel motion is possible. The
HST electronic control
function (Mode 3) is in the
inoperative condition
–
Check the Hi-Lo solenoid
resistance
Replace the Hi-Lo solenoid
ERROR No. 93
Starter RELAY NG
Starter relay is in trouble
• Starter relay failure
• Wiring for starter relay is
disconnected or short-circuited
Engine does not start
–
Replace the starter relay
Check the wiring connector of
starter relay
–
ERROR No. 94
OPC NG
OPC is in trouble
• Wiring for OPC is disconnected
or short-circuited
Engine is stopped
–
Check the wiring connector of
OPC
Check the communication line
between terminal B18 of main
ECU and terminal 20 of
engine ECU
–
ERROR No. 95
PTO SOLENOID NG
Solenoid (PTO) is in
trouble
• PTO solenoid valve failure
• Wiring for PTO solenoid valve
is disconnected or
short-circuited
• Grounding plate of solenoid is
poor contact with chassis
PTO does not rotate
–
Check the PTO solenoid valve
Replace the PTO solenoid
valve
Check the wiring connector of
PTO solenoid valve
–
Display on IntelliPanel
Trouble Item
Probable Cause
Solution
Reference
Page
KiSC issued 03, 2016 A
Summary of Contents for WSM L3560
Page 1: ...L3560 L4060 L4760 L5060 L5460 L6060 WORKSHOP MANUAL TRACTOR KiSC issued 03 2016 A...
Page 5: ...I INFORMATION KiSC issued 03 2016 A...
Page 28: ...G GENERAL KiSC issued 03 2016 A...
Page 114: ...1 ENGINE KiSC issued 03 2016 A...
Page 241: ...2 CLUTCH KiSC issued 03 2016 A...
Page 242: ...CONTENTS 1 FEATURE 2 M1 MECHANISM KiSC issued 03 2016 A...
Page 275: ...3 TRANSMISSION KiSC issued 03 2016 A...
Page 454: ...4 REAR AXLE KiSC issued 03 2016 A...
Page 455: ...CONTENTS 1 STRUCTURE 4 M1 MECHANISM KiSC issued 03 2016 A...
Page 466: ...5 BRAKES KiSC issued 03 2016 A...
Page 467: ...CONTENTS 1 STRUCTURE 5 M1 2 OPERATION 5 M2 MECHANISM KiSC issued 03 2016 A...
Page 486: ...6 FRONT AXLE KiSC issued 03 2016 A...
Page 487: ...CONTENTS 1 STRUCTURE 6 M1 MECHANISM KiSC issued 03 2016 A...
Page 511: ...7 STEERING KiSC issued 03 2016 A...
Page 528: ...8 HYDRAULIC SYSTEM KiSC issued 03 2016 A...
Page 585: ...9 ELECTRICAL SYSTEM KiSC issued 03 2016 A...
Page 736: ...10 CABIN KiSC issued 03 2016 A...