9Y1210824ENS0002US0
Item
Factory Specification
Allowable Limit
Fan Belt
Tension
7.0 to 9.0 mm (0.28 to
0.35 in.) deflection at
98 N (10 kgf, 22 lbf) of
force
–
Thermostat Valve
Opening-
Temperature
(When the valve
starts to open)
Opening-
Temperature
(When the valve
opened
completely)
80.5 to 83.5 °C
176.9 to 182.3 °F
95 °C
203 °F
–
–
Radiator
Water Tightness
No leak at
specified pressure
–
Radiator Cap
Pressure
Decreasing Time
More than 10 seconds
for pressure decrease
from 90 to 60 kPa
from 0.9 to 0.6 kgf/cm
2
from 10 to 9 psi
–
KiSC issued 03, 2016 A
Summary of Contents for WSM L3560
Page 1: ...L3560 L4060 L4760 L5060 L5460 L6060 WORKSHOP MANUAL TRACTOR KiSC issued 03 2016 A...
Page 5: ...I INFORMATION KiSC issued 03 2016 A...
Page 28: ...G GENERAL KiSC issued 03 2016 A...
Page 114: ...1 ENGINE KiSC issued 03 2016 A...
Page 241: ...2 CLUTCH KiSC issued 03 2016 A...
Page 242: ...CONTENTS 1 FEATURE 2 M1 MECHANISM KiSC issued 03 2016 A...
Page 275: ...3 TRANSMISSION KiSC issued 03 2016 A...
Page 454: ...4 REAR AXLE KiSC issued 03 2016 A...
Page 455: ...CONTENTS 1 STRUCTURE 4 M1 MECHANISM KiSC issued 03 2016 A...
Page 466: ...5 BRAKES KiSC issued 03 2016 A...
Page 467: ...CONTENTS 1 STRUCTURE 5 M1 2 OPERATION 5 M2 MECHANISM KiSC issued 03 2016 A...
Page 486: ...6 FRONT AXLE KiSC issued 03 2016 A...
Page 487: ...CONTENTS 1 STRUCTURE 6 M1 MECHANISM KiSC issued 03 2016 A...
Page 511: ...7 STEERING KiSC issued 03 2016 A...
Page 528: ...8 HYDRAULIC SYSTEM KiSC issued 03 2016 A...
Page 585: ...9 ELECTRICAL SYSTEM KiSC issued 03 2016 A...
Page 736: ...10 CABIN KiSC issued 03 2016 A...