24
IGNITION SYSTEM
204
601207-10
–
Measure the resistance between the specified points.
Measuring point 1
–
Measuring point 2
Spark plug connector
Resistance at: 20 °C (68 °F)
4.3… 5.7 k
Ω
» If the specification is not reached:
–
Change the spark plug connector.
24.5
Alternator - checking the charging coil of the ignition
Condition
The alternator has been disconnected.
601213-10
–
Measure the resistance between the specified points.
Alternator, charging coil/ignition pulse generator, connector
AN
pin
1
–
Alternator, charging coil/ignition pulse generator, connector
AN
pin
2
Alternator
Resistance of ignition charging coil
at: 20 °C (68 °F)
12… 16.5
Ω
» The specifications have not been met:
–
Replace the stator.
601213-10
601223-10
–
Measure the resistance between the specified points.
Alternator, charging coil/ignition pulse generator, connector
AN
pin
1
–
Measuring point Ground, wiring harness/frame
Resistance
∞ Ω
» The specifications have not been met:
–
Replace the stator.
24.6
Alternator - checking the battery winding
Condition
The alternator has been disconnected.
601221-10
600897-10
–
Measure the resistance between the specified points.
Alternator, connector
CR
pin
1
(White)
–
Measuring point
Ground (
−
)
Alternator
Battery winding resistance at: 20 °C (68 °F)
0.5… 0.9
Ω