VI - 10
Maintenance
6.8.3 Scraper-floor drive unit
The scraper-floor drive unit is located at the rear on the
right hand side.
Oil inspection:
• Remove check screw (1)
• Oil level up to bore hole (1)
• If necessary, top up oil (SAE 90), fit
check screw (1)
Oil change:
• Unscrew the oil draining screw (2)
• Collect the used oil in a suitable collection vessel.
• Fit oil draining screw (2)
• Fill oil (1) (Oil level up to bore hole (1))
6.8.4 Metering rollers drive
a) Front metering rollers drive
b) The rear metering rollers drive is on the left side under
the cover.
Oil change:
• Remove oil drain plug (2)
• Collect oil in a suitable vessel
• Replace oil drain plug (2)
• Fill oil (1) (oil level to hole (1))
Oil check:
• Remove check screw (1)
• Check oil level is up to hole (1)
• Top up with oil if necessary
Replace check screw (1)
Oil change:
• Unscrew oil drain plug (2)
• Catch oil in a suitable vessel
• Replace oil drain plug (2)
• Fill oil (1) (oil level to hole (1))
Oil check:
• Remove check screw (1)
• Check oil level is up to hole (1)
• Top up with oil if necessary
Replace check screw (1)
6XL00002
2
1
KDW06332
1
2
2
1
TR000031