VI - 6
Maintenance
6.5.2 Adjusting the sensors
a
BPXC0172
2
1
3
a
BP-VFS-088-1
2
1
3
Namur sensor d = 12 mm
The dimension between the encoder (2) and the sensor
(1) must be
“a“ = 2 mm
.
Setting
•
Loosen the nuts on either side of the sensor.
•
Turn the nuts until dimension
“a” = 2 mm
is
reached.
•
Tighten the nuts again.
Namur sensor d = 30 mm
The dimension between the encoder (2) and the sensor
(1) must be
“a” = 5 mm
.
Setting
•
Loosen the nuts on either side of the sensor.
•
Turn the nuts until dimension
“a” = 5 mm
is
reached.
•
Tighten the nuts again.