IV - 25
Comfort Control Unit
Setting values:
The minimum and maximum setting values with the
sensor alive (metal in front of the sensor) are shown in
the upper part of the bar display.
The current setting value (actual value) is displayed
under the bar display.
The distance from the sensor to the metal must be
adjusted so that in the alive state, the bar lies in the
upper marked area.
Then check whether the bar is in the alive state in the
lower marked area.
Diagnostics – Namur sensors
Possible sensors
(depending on how the machine is equipped)
L400201
Status (state):
•
Axle blocked
•
Axle free
Diagnosis pressure sensors
Possible sensors
(depending on how the machine is equipped)
No.
Sensor icon
Description
B7
Axle blocked
Status (state):
•
Alive (iron)
•
Not alive (no iron)
•
Broken cable
•
Short circuit
No.
Sensor icon
Description
B1
Blades active
B2
Automatic loader
B3
Floor conveyor shutdown
B4
Metering rollers (GD)
B5
PTO speed (GD)
B6
Tailgate
Tailgate closed (ZX)
B8
Tailgate
open
(GD)
DL400570