K-CONFIG –
Connecting to the Device
161
The following table summarizes the date and time setting options:
Set Date and Time
Procedure
From a connected PC Clock 1. Click the “Set Now”
button.
2. Click Read (from device)
to check the updated values.
If you want the time and date to be set whenever writing a configuration, check “Set from PC on
Write Configuration”.
Manually
1. Click the dropdown box.
2. Select the desired date
and time from the dropdown
box.
3. Click the Set Now button.
4. Click Read (
from room
controller
device
) to check
the updated values.
From a server address
1. In the Sync Date and
Time area, check “From
Server Address”.
2. Type the IP address.
For example, 192.168.0.6
3. Set the DST to ON (for
adjusting the time to the
“summer” clock) if required
4. Set the time zone
according to UTC.
For example, the time in
Jerusalem is
UTC +2:00.
5. Click the Read (
from
server
) button (below the IP
number).
6. Click Read (
from device
)
to check the updated values.
The room controller device
updated date and time
appear
In case there was a problem
reading the date and time,
the following message
appears: