K-CONFIG –
Assigning the Controlled Devices to Master and Auxiliary Device Ports
101
When defining the ports of a master room controller which is Site-CTRL compatible, check the radio button
“Main” to select the port which will appear in the main display of the Master room controller Web pages. The
same display device will be monitored in the Site-CTRL overview page.
You can click the clear button to reset the port to its default state (no driver attached).
The driver that was assigned to the RS-232 port in the port manager will now appear automatically in the
Action
Editor
area when that port is selected:
Figure 187: Action Editor – Automatic Driver Selection
Note that the driver should always be set via the Port Manager. Driver settings that are made via the Action
Editor are not saved, and need to be set again every time an action is defined.
The Project Navigator shows the assigned controlled devices in their appropriate place. For example, the VPL-PX41
projector (described as Room 1 - Projector), appears under the Master room controller
RC-74DL
and the Kramer
VP-771
scaler which was assigned to the RS-232 port of the
RC-63DL
auxiliary device (procedure not shown here)
appears under
RC-63DL
:
Figure 188: Project Navigator – Display of the Assigned Drivers
In the same way any assigned device, will show in the Project navigator (for example, controlled devices connected via
the
RS-232 port, RS-485 port, IR OUT port, relays, and so on).