4. PERIODICAL MAINTENANCE PROCEDURE
21
bizhub C35
MAINTENANCE
4.
Pull down two levers [1].
5.
Remove the fuser unit [1].
6.
Install the new fuser unit.
7.
From the Menu, select [Service Mode]
→
[Supplies]
→
[Consumables Replace]
→
[Fusing Unit] and execute this function to reset the fuser unit counter value.
A121F2C523DA
[1]
A121F2C524DA
[1]